Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.966
Filtrar
1.
Sci Rep ; 14(1): 8647, 2024 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622221

RESUMEN

Systematic culture of the tip of central lines is performed in many neonatal intensive care units (NICUs) to guide any subsequent antibiotic therapy. The clinical relevance of this procedure is debated, given the significant bacterial contamination during its removal. We aimed to describe infections related to catheters and assess the usefulness of central catheter systematic cultures for probabilistic antibiotic therapy in cases of suspicion of catheter-related infections in a NICU. A retrospective study in a NICU included all newborn patients hospitalized with a central catheter, between January 2018, and June 2019. The main outcome measures were bacterial catheter colonization, catheter-related infection rate, and simulation-based approach to antibiotic prescription. Three hundred and seventy-five newborns, with 634 central catheters were included. There were 273 (43%) catheters that were colonized by at least one microorganism. There were 183 cases of suspected sepsis, with 31 infections definitively related to the catheter. In our simulation antibiotic prescription approach, there was no significant difference in terms of the efficacy toward the microorganism(s) involved between the probabilistic antibiotic therapies proposed by the experts and those ultimately prescribed. Performing a catheter culture only if catheter-related infection is suspected could be an alternative to routine screening.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Humanos , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Infecciones Relacionadas con Catéteres/tratamiento farmacológico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Venoso Central/métodos , Estudios Retrospectivos , Catéteres Venosos Centrales/efectos adversos , Catéteres Venosos Centrales/microbiología , Antibacterianos/uso terapéutico
2.
Antimicrob Resist Infect Control ; 13(1): 40, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38605403

RESUMEN

In the healthcare sector, the implementation of standardized procedures, such as those commonly employed in franchises to ensure consistent quality, remains underprioritized. Within this framework, we focus on the importance of standardized central venous catheter (CVC) insertion procedures to prevent healthcare-associated outbreaks. While antimicrobial resistance (AMR) may still not be the most prevalent problem in some institutions, its increasing significance certainly underlines the urgency of infection prevention.We aim to highlight this issue by describing and discussing an outbreak scenario of carbapenem-resistant (CR) Pseudomonas fluorescens bloodstream infections resulting from a deviation from the standardized CVC insertion procedure. This outbreak led to six episodes of catheter related bloodstream infection (CRBSI) in patients with hematologic malignancies, delaying their primary treatment. Nineteen patients were exposed, leading to an attack rate of 31.6%.


Asunto(s)
Bacteriemia , Infecciones Relacionadas con Catéteres , Pseudomonas fluorescens , Humanos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Catéteres/epidemiología , Bacteriemia/epidemiología , Farmacorresistencia Bacteriana , Brotes de Enfermedades , Estándares de Referencia
3.
J Vis Exp ; (205)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38587399

RESUMEN

Catheter-related infection (CRI) is a common nosocomial infection caused by candida albicans during catheter implantation. Typically, biofilms are formed on the outer surface of the catheter and lead to disseminated infections, which are fatal to patients. There are no effective prevention and treatment management in clinics. Therefore, it is urgent to establish an animal model of CRI for the preclinical screening of new strategies for its prevention and treatment. In this study, a polyethylene catheter, a widely used medical catheter, was inserted into the back of the BALB/c mice after hair removal. Candida albicans ATCC MYA-2876 (SC5314) expressing enhanced green fluorescent protein was subsequently inoculated on the skin's surface along the catheter. Intense fluorescence was observed on the surface of the catheter under a fluorescent microscope 3 days later. Mature and thick biofilms were found on the surface of the catheter via scanning electron microscopy. These results indicated the adhesion, colonization, and biofilm formation of candida albicans on the surface of the catheter. The hyperplasia of the epidermis and the infiltration of inflammatory cells in the skin specimens indicated the histopathological changes of the CRI-associated skin. To sum up, a mouse CRI model was successfully established. This model is expected to be helpful in the research and development of therapeutic management for candida albicans associated CRI.


Asunto(s)
Candida albicans , Infecciones Relacionadas con Catéteres , Humanos , Ratones , Animales , Catéteres , Modelos Animales de Enfermedad , Biopelículas , Antifúngicos
4.
BMC Nephrol ; 25(1): 126, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589798

RESUMEN

OBJECTIVE: To provide theoretical basis for prevention of a Dacron-cuffed catheter related infection (CRI), the risk factors of CRI in hemodialysis patients were systematically evaluated. METHODS: Eight databases, including PubMed, Cochrane library, EMBASE, Web of Science, China National Knowledge Infrastructure (CNKI), Chinese Biomedical Database (CBM), Wanfang Database and Chinese Scientific Journal Database (VIP), were searched to screen out literatures related to the risk factors of long-term indwelling a Dacron-cuffed CRI in hemodialysis. Meta-analysis of risk factors for a Dacron-cuffed CRI in hemodialysis and publication bias test were performed using RevMan 5.4 software. RESULTS: After screening, 13 literatures involving a Dacron-cuffed CRI were included, with a total of 625 patients, and the infection rate was 11.7%. The combined OR value and 95% confidence interval (CI) of all factors were: Combined with Diabetes (1.94, 1.51 ~ 2.50), Hb (1.82, 1.35 ~ 2.44), age (2.38, 1.06 ~ 5.34), catheter indwelling time (1.79, 1.21 ~ 2.66), serum albumin (2.26, 1.25 ~ 4.08), catheter indwelling site (3.29, 1.74 ~ 6.23) and the number of tube placement (5.40, 2.65 ~ 11.02). CONCLUSIONS: The main risk factors for a Dacron-cuffed CRI in hemodialysis were combined with diabetes, hemoglobin level, age, catheter indwelling time, serum albumin level, femoral vein catheter indwelling and catheterization times. In other words, hemodialysis patients are at higher risk of CRI if they have diabetes, or if they have a lower hemoglobin level, or if they are older, or if they have a longer duration of catheterization, or if they have a lower serum albumin level, or if they have a femoral vein catheter, or if they have more catheters.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Diabetes Mellitus , Humanos , Infecciones Relacionadas con Catéteres/etiología , Tereftalatos Polietilenos , Diálisis Renal/efectos adversos , Catéteres de Permanencia/efectos adversos , Cateterismo Venoso Central/efectos adversos , Factores de Riesgo , Diabetes Mellitus/etiología , Albúmina Sérica , Hemoglobinas
5.
Trials ; 25(1): 249, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38594766

RESUMEN

BACKGROUND: Malignant pleural effusion (MPE) is a debilitating condition as it commonly causes disabling breathlessness and impairs quality of life (QoL). Indwelling pleural catheter (IPC) offers an effective alternative for the management of MPE. However, IPC-related infections remain a significant concern and there are currently no long-term strategies for their prevention. The Australasian Malignant PLeural Effusion (AMPLE)-4 trial is a multicentre randomised trial that evaluates the use of topical mupirocin prophylaxis (vs no mupirocin) to reduce catheter-related infections in patients with MPE treated with an IPC. METHODS: A pragmatic, multi-centre, open-labelled, randomised trial. Eligible patients with MPE and an IPC will be randomised 1:1 to either regular topical mupirocin prophylaxis or no mupirocin (standard care). For the interventional arm, topical mupirocin will be applied around the IPC exit-site after each drainage, at least twice weekly. Weekly follow-up via phone calls or in person will be conducted for up to 6 months. The primary outcome is the percentage of patients who develop an IPC-related (pleural, skin, or tract) infection between the time of catheter insertion and end of follow-up period. Secondary outcomes include analyses of infection (types and episodes), hospitalisation days, health economics, adverse events, and survival. Subject to interim analyses, the trial will recruit up to 418 participants. DISCUSSION: Results from this trial will determine the efficacy of mupirocin prophylaxis in patients who require IPC for MPE. It will provide data on infection rates, microbiology, and potentially infection pathways associated with IPC-related infections. ETHICS AND DISSEMINATION: Sir Charles Gairdner and Osborne Park Health Care Group Human Research Ethics Committee has approved the study (RGS0000005920). Results will be published in peer-reviewed journals and presented at scientific conferences. TRIAL REGISTRATION: Australia New Zealand Clinical Trial Registry ACTRN12623000253606. Registered on 9 March 2023.


Asunto(s)
Infecciones Relacionadas con Catéteres , Derrame Pleural Maligno , Humanos , Derrame Pleural Maligno/diagnóstico , Derrame Pleural Maligno/complicaciones , Calidad de Vida , Mupirocina/efectos adversos , Pleurodesia/métodos , Talco/uso terapéutico , Catéteres de Permanencia/efectos adversos , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/prevención & control , Antibacterianos/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
6.
Pol Merkur Lekarski ; 52(2): 137-144, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38642348

RESUMEN

OBJECTIVE: Aim: to investigate the epidemiology, microbiology, and risk factors for healthcare-associated infections (HAIs) in postoperative patients with intracranial aneurysm in Ukraine. PATIENTS AND METHODS: Materials and Methods: Retrospective cohort study was conducted from January 2018 to December 2022 in four tertiary care hospitals of Ukraine. The diagnostic criteria were based on specific HAI site were adapted from the CDC/NHSN case definitions. RESULTS: Results: Of 1,084 postoperative patients with intracranial aneurysm, 128 (11.4%) HAIs were observed. The most common of HAI type was possible ventilatorassociated pneumonia (38.2%) followed by central line-associated bloodstream infections (33.8%), catheter -associated urinary tract infection (18.5%), and surgical site infection (9.6%). Inpatient mortality from HAI was 5.1%. Emergency admission, mechanical ventilation, taking antiplatelet aggregation drugs, albumin reduction, hyperglycaemia, hyponatremia, surgical procedure, operation time > 4 h, mechanical ventilation, urinary catheter, and central venous catheterization were risk factors associated with HAI in patients with intracranial aneurysm surgery. A total of 26% cases of HAIs by MDROs were notified over the study period. Klebsiella spp. - essentially K. pneumoniae - were the most frequent, followed by Enterobacter spp. and Escherichia coli. Carbapenemase production in Enterobacterales constituted the most frequent mechanism of resistance, while ESBL-production in Enterobacterales and meticillin-resistance in Staphylococcus aureus (MRSA) were detected in 65,7% 62,3% and 20% of cases, respectively. CONCLUSION: Conclusions: The present study showed that HAIs is a common complication in postoperative patients with intracranial aneurysm in Ukraine and multidrugresistant organisms the major pathogen causing infection.


Asunto(s)
Infecciones Relacionadas con Catéteres , Infección Hospitalaria , Aneurisma Intracraneal , Infecciones Urinarias , Humanos , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Estudios Retrospectivos , Ucrania/epidemiología , Aneurisma Intracraneal/epidemiología , Aneurisma Intracraneal/cirugía , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Atención a la Salud , Antibacterianos
7.
Antimicrob Resist Infect Control ; 13(1): 38, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600526

RESUMEN

BACKGROUND: Most surveillance systems for catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI) are based on manual chart review. Our objective was to validate a fully automated algorithm for CRBSI and CLABSI surveillance in intensive care units (ICU). METHODS: We developed a fully automated algorithm to detect CRBSI, CLABSI and ICU-onset bloodstream infections (ICU-BSI) in patients admitted to the ICU of a tertiary care hospital in Switzerland. The parameters included in the algorithm were based on a recently performed systematic review. Structured data on demographics, administrative data, central vascular catheter and microbiological results (blood cultures and other clinical cultures) obtained from the hospital's data warehouse were processed by the algorithm. Validation for CRBSI was performed by comparing results with prospective manual BSI surveillance data over a 6-year period. CLABSI were retrospectively assessed over a 2-year period. RESULTS: From January 2016 to December 2021, 854 positive blood cultures were identified in 346 ICU patients. The median age was 61.7 years [IQR 50-70]; 205 (24%) positive samples were collected from female patients. The algorithm detected 5 CRBSI, 109 CLABSI and 280 ICU-BSI. The overall CRBSI and CLABSI incidence rates determined by automated surveillance for the period 2016 to 2021 were 0.18/1000 catheter-days (95% CI 0.06-0.41) and 3.86/1000 catheter days (95% CI: 3.17-4.65). The sensitivity, specificity, positive predictive and negative predictive values of the algorithm for CRBSI, were 83% (95% CI 43.7-96.9), 100% (95% CI 99.5-100), 100% (95% CI 56.5-100), and 99.9% (95% CI 99.2-100), respectively. One CRBSI was misclassified as an ICU-BSI by the algorithm because the same bacterium was identified in the blood culture and in a lower respiratory tract specimen. Manual review of CLABSI from January 2020 to December 2021 (n = 51) did not identify any errors in the algorithm. CONCLUSIONS: A fully automated algorithm for CRBSI and CLABSI detection in critically-ill patients using only structured data provided valid results. The next step will be to assess the feasibility and external validity of implementing it in several hospitals with different electronic health record systems.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Infección Hospitalaria , Sepsis , Humanos , Femenino , Persona de Mediana Edad , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Estudios Prospectivos , Estudios Retrospectivos , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Catéteres , Algoritmos
8.
J Clin Apher ; 39(3): e22111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38634439

RESUMEN

The objective of this study was to assess the use of midline catheters as venous access for apheresis procedures in pediatric patients. A retrospective analysis of medical records was conducted from September 2019 to June 2022 to evaluate the safety and efficacy of midline catheters for therapeutic pediatric apheresis. During the study period, a total of 121 procedures were inserted in 22 unique patients. The age of the subjects ranged from 2.7 to 21 years. The blood flow rates achieved with midline catheters met or exceeded the recommended rates for apheresis in children (40 mL/min), by the Wilcoxon signed-rank test (p < 0.0001). There was one episode of catheter-related thrombosis, but no cases of bloodstream infection or catheter dislodgement were reported. In conclusion, this study supports the use of midline catheters as a safe and effective alternative for venous access during therapeutic and donor apheresis procedures in pediatric patients.


Asunto(s)
Eliminación de Componentes Sanguíneos , Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Trombosis , Humanos , Niño , Preescolar , Adolescente , Adulto Joven , Adulto , Cateterismo Venoso Central/métodos , Estudios Retrospectivos , Catéteres , Eliminación de Componentes Sanguíneos/métodos , Cateterismo Periférico/métodos
9.
Expert Rev Med Devices ; 21(3): 207-216, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38445649

RESUMEN

INTRODUCTION: More than 30% of peripherally inserted central catheters (PICCs) and midline catheters experience complications. Most complications are related to thrombotic cellular adherence to catheter materials. AREAS COVERED: This manuscript outlines PICC and midline catheter complications, the need to reduce complications and how hydrogel catheters may provide a solution to address these unmet needs based on available evidence. EXPERT OPINION: Patients commonly require PICC or midline catheters for treatment to establish a reliable form of intravenous access. Catheters, while reliable in most cases, are not without complications, including occlusion, thrombosis and infection, each related to cellular adherence to the catheter material. Hydrophilic catheter coatings and composites have been developed to mitigate these thrombotic complications, reduce adherence of blood and bacterial cells to catheters and provide greater patient safety with these devices. Hydrogel materials are highly biocompatible and have been effective in reducing cellular adherence and the formation of biofilms on surfaces. Smooth hydrophilic catheter surfaces are potentially more comfortable for the patient, with reduced friction during insertion and removal. A catheter constructed of hydrophilic biomaterial, a hydrogel composite material, may minimize thrombotic complications in PICC and midline catheters, improving catheter performance and outcomes for patients.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Trombosis , Humanos , Cateterismo Venoso Central/efectos adversos , Infecciones Relacionadas con Catéteres/microbiología , Hidrogeles , Catéteres , Trombosis/etiología , Cateterismo Periférico/efectos adversos , Factores de Riesgo , Estudios Retrospectivos , Catéteres de Permanencia/efectos adversos
10.
Medicine (Baltimore) ; 103(12): e37184, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38518044

RESUMEN

To investigate the incidence, risk factors, and pathogenic characteristics of catheter-related bloodstream infection caused by peripherally inserted central venous catheter in neonates, and to provide references for reducing the infection rate of peripherally inserted central venous catheter. The clinical data of 680 neonates who underwent peripherally inserted central catheter (PICC) in the neonatal intensive care unit from June 2020 to June 2023 were retrospectively analyzed. The risk factors and independent risk factors of catheter-related bloodstream infection caused by PICC were determined by univariate and multivariate analysis, respectively. Catheter-related bloodstream infection occurred in 38 of 680 neonates who underwent PICC. The infection rate was 4.74%. The proportions of fungi, gram-positive bacteria, and gram-negative bacteria were 42.11%, 36.84%, and 21.05%, respectively. Candida parapsilosis was the main fungus (18.42%), coagulase negative Staphylococcus was the main gram-positive bacteria (23.68%), and Klebsiella pneumoniae and Escherichia coli were the main gram-negative bacteria (7.89%). Univariate analysis showed that gestational age ≤32 weeks, birth weight ≤1500 g, congenital diseases, nutritional support, catheterization time, 5-minute APGAR score ≤7, and neonatal respiratory distress syndrome were associated with catheter-related bloodstream infection caused by PICC. Multivariate analysis showed that premature delivery, low birth weight, parenteral nutrition, long catheterization time, and 5-minute APGAR score ≤7 were associated with catheter-related bloodstream infection caused by PICC. Among the pathogens detected, there were 6 cases of K pneumoniae, 5 cases of coagulase negative staphylococci, and 2 cases of fungi. Low birth weight, premature delivery, off-site nutrition, long catheterization time, and 5-minute APGAR score ≤7 are independent risk factors for catheter-related bloodstream infection in neonates with peripherally inserted central venous catheters. The pathogenic bacteria are fungi and multidrug-resistant bacteria.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Sepsis , Recién Nacido , Humanos , Lactante , Estudios Retrospectivos , Coagulasa , Infecciones Relacionadas con Catéteres/microbiología , Sepsis/etiología , Cateterismo Periférico/efectos adversos , Factores de Riesgo , Cateterismo Venoso Central/efectos adversos
11.
J Infect Public Health ; 17(5): 825-832, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38537577

RESUMEN

BACKGROUND: Catheter-associated urinary tract infections (CAUTIs) are the most common device-associated healthcare-acquired infections and pose a significant burden on patients and healthcare systems worldwide. However, there is a paucity of data on CAUTI epidemiology and microbiology in the Middle East and North Africa (MENA) region, including Lebanon. METHODS: This 14-year retrospective cohort study was conducted at a tertiary care center in Lebanon. It analyzed data on all adult patients diagnosed with CAUTI between January 2009 and December 2022 in intensive care units (ICUs) and between June 2011 and December 2022 in regular units. Incidence rates, urinary catheter utilization ratios, and microbiological profiles were collected and analyzed. RESULTS: A total of 620 CAUTI cases were identified during the study period. The overall CAUTI rate was 2.4 per 1000 catheter-days, with higher rates in ICUs (3.2 per 1000 catheter-days) compared to regular units (1.4 per 1000 catheter-days). No significant changes in the rates were noted despite implementing many interventions. The most common pathogens were Gram-negative bacteria, with Escherichia coli, Pseudomonas aeruginosa, and Klebsiella pneumoniae being predominant. Multidrug-resistant organisms represented 48% of all isolates. Enterobacterales were largely extended-spectrum ß-lactamase (ESBL) producing, and most Acinetobacter baumannii isolates showed multidrug resistance. CONCLUSIONS: This study provides important insights into CAUTI epidemiology and microbiology in a tertiary care center in Lebanon, addressing the knowledge gap in this area in the MENA region. Despite implementing prevention measures, CAUTI rates remained stable over the 14-year period. The findings highlight the need for continuous improvement in infection prevention practices, diagnostic stewardship, and antimicrobial stewardship, especially given the rising threat of antimicrobial resistance. These results can serve as a guide for the development of targeted preventive strategies to reduce the burden of CAUTIs, particularly in low- and middle-income countries where antimicrobial resistance is a major issue.


Asunto(s)
Antiinfecciosos , Infecciones Relacionadas con Catéteres , Infección Hospitalaria , Infecciones Urinarias , Adulto , Humanos , Infecciones Relacionadas con Catéteres/prevención & control , Centros de Atención Terciaria , Estudios Retrospectivos , Líbano/epidemiología , Infecciones Urinarias/microbiología , Unidades de Cuidados Intensivos , Catéteres/efectos adversos , Infección Hospitalaria/microbiología
12.
J Infect Public Health ; 17(4): 687-695, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38471259

RESUMEN

BACKGROUND: Surveillance of healthcare-associated infections (HAIs) is an essential component of hospital infection prevention and control systems. We aimed to assess the quality of the data compiled by the Brazilian HAI Surveillance System from pediatric (PICUs) and neonatal intensive care units (NICUs), between 2012 and 2021. METHODS: Data Quality Review, including adherence, completeness, internal consistency, consistency over time, and consistency of population trend, were computed at both national and state levels based on quality metrics from World Health Organization Toolkit. Incidence rates (or incidence density) of ventilator-associated pneumonia (VAP) and central line-associated bloodstream infection (CLABSI) were obtained from the Brazilian National Nosocomial Infections Surveillance (NNIS) system. Data on sepsis-related mortality, spanning the period from 2012 to 2021, were extracted from the Brazilian National Health Service database (DATASUS). Additionally, correlations between sepsis-related mortality and incidence rates of VAP or CLABSI were calculated. RESULTS: Throughout the majority of the study period, adherence to VAP reporting remained below 75%, exhibiting a positive trend post-2016. Widespread outliers, as well as inconsistencies over time and in population trends, were evident across all 27 states. Only four states maintained consistent adherence levels above 75% for more than 8 years regarding HAI incidence rates. Notably, CLABSI in NICUs boasted the highest reporting adherence among all HAIs, with 148 periods out of 270 (54.8%) exhibiting reporting adherence surpassing 75%. Three states achieved commendable metrics for CLABSI in PICUs, while five states demonstrated favorable results for CLABSI in NICUs. CONCLUSIONS: While adherence to HAI report is improving among Brazilian states, an important room for improvement in the Brazilian NNIS exists. Additional efforts should be made by the Brazilian government to improve the reliability of HAI data, which could serve as valuable guidance for hospital infection prevention and control policies.


Asunto(s)
Infecciones Relacionadas con Catéteres , Infección Hospitalaria , Neumonía Asociada al Ventilador , Sepsis , Recién Nacido , Humanos , Niño , Infección Hospitalaria/prevención & control , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/prevención & control , Exactitud de los Datos , Brasil/epidemiología , Reproducibilidad de los Resultados , Medicina Estatal , Sepsis/epidemiología , Sepsis/complicaciones , Neumonía Asociada al Ventilador/epidemiología , Unidades de Cuidados Intensivos
14.
PLoS One ; 19(3): e0299715, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38536779

RESUMEN

OBJECTIVE: This meta-analysis aimed to elucidate the risk factors contributing to catheter-associated bloodstream infection in hemodialysis patients. METHODS: Comprehensive literature searches were conducted in both English and Chinese databases, which encompassed PubMed, Cochrane Library, Embase, CNKI, Wanfang Data, VIP Database and China Biomedical Literature Database. The search timeframe extended from each database's inception to March 8, 2023. Two independent researchers executed literature screening, data extraction, and quality assessment using the Newcastle-Ottawa Scale. Statistical analysis of the data was performed using RevMan 5.3 software, facilitating the identification of significant risk factors associated with catheter-related bloodstream infections in hemodialysis patients. This meta-analysis is registered with PROSPERO under the registration number CRD42023406223. RESULTS: Forty-nine studies were incorporated into this meta-analysis, from which 22 risk factors were examined. Through the analysis, 17 risk factors exhibited statistical significance (P < 0.05): age (OR = 1.52, 95% CI [0.49, 4.68]), diabetes (OR = 2.52, 95% CI [1.95, 3.25]), kidney disease (OR = 3.45, 95% CI [1.71, 6.96]), history of catheter-associated infection (OR = 2.79, 95% CI [1.96, 3.98]), hypertension (OR = 1.43, 95% CI [1.08, 1.91]), dialysis duration (OR = 3.06, 95% CI [1.70, 5.50]), catheter placement site (OR = 1.91, 95%CI [1.35, 2.70]), catheter duration (OR = 2.06, 95% CI [1.17, 3.60]), number of catheterizations (OR = 4.22, 95% CI [3.32, 5.37]), catheter types (OR = 3.83, 95% CI [2.13, 6.87]), CD4+ cells (OR = 0.33, 95% CI [0.18, 0.63]), albumin (ALB, OR = 2.12, 95% CI [1.15, 3.91]), C-reactive protein (CRP, OR = 1.73, 95% CI [1.47, 2.03]), hemoglobin (Hb, OR = 1.48, 95% CI [0.54, 4.07]), procalcitonin (PCT, OR = 1.05, 95% CI [1.03, 1.06]), inadequate hand hygiene (OR = 5.32, 95% CI [1.07, 26.37]), and APACHE II scores (OR = 2.41, 95% CI [1.33, 4.37]). CONCLUSION: This meta-analysis suggests that age, diabetes, kidney disease, history of catheter-associated infection, hypertension, dialysis duration, catheter placement site, catheter duration, number of catheterizations, catheter type, CD4+ cells, albumin, C-reactive protein, hemoglobin, procalcitonin, inadequate hand hygiene, and APACHE II scores significantly influence the incidence of catheter-associated bloodstream infection in hemodialysis patients.


Asunto(s)
Infecciones Relacionadas con Catéteres , Diabetes Mellitus , Hipertensión , Enfermedades Renales , Sepsis , Humanos , Diálisis Renal/efectos adversos , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/etiología , Infecciones Relacionadas con Catéteres/prevención & control , Proteína C-Reactiva , Polipéptido alfa Relacionado con Calcitonina , Catéteres/efectos adversos , Sepsis/etiología , Factores de Riesgo , Diabetes Mellitus/etiología , Hemoglobinas , Hipertensión/complicaciones , Enfermedades Renales/etiología
15.
Wiad Lek ; 77(1): 17-24, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38431802

RESUMEN

OBJECTIVE: Aim: To investigate the epidemiology, microbiology, and risk factors for healthcare-associated infections (HAIs) after a neurosurgical procedure in Ukraine. PATIENTS AND METHODS: Materials and Methods: Prospective multicentre surveillance was conducted from January 2020 to December 2022 in 10 regional hospitals of Ukraine. Definitions of HAIs were adapted from the Centers for Disease Control and Prevention's National Healthcare Safety Network. RESULTS: Results: Of 8,623 neurosurgical patients, 1,579 (18.3%) HAIs were observed. The most frequently of HAI types were pneumonia (38.4%), surgical site infection (34.2%), urinary tract infection (18.1%) and bloodstream infection (9.3%). Death during hospitalization was reported in 11.3% of HAI cases. There was an association between HAIs after neurosurgical procedures and patients with diabetes mellitus, end-stage renal disease undergoing dialysis, and leukaemia. The strongest independent associations were observed for intubation, urinary catheters, and vascular catheters. Klebsiella pneumoniae were most commonly reported, accounting for 25.1% of all organisms, followed by Escherichia coli (17.6%), Staphylococcus aureus (9.9%), Pseudomonas aeruginosa (8.9%), Acinetobacter baumannii (8.5%), coagulase-negative staphylococci (6.8%), and Streptococcus spp. (5.5%). In total, 76.3% isolates from neurosurgical patients were MDROs. Antimicrobial resistance in Ukraine varies greatly by bacterial species, antimicrobial group, and region. CONCLUSION: Conclusions: Healthcare-associated infections are a cause for mortality and morbidity among neurosurgical patients. This is due to increase emergence of antimicrobial-resistant pathogens. Routinely collected surveillance data are of great value as a basis for studying the consequences of HAIs.


Asunto(s)
Antiinfecciosos , Infecciones Relacionadas con Catéteres , Infección Hospitalaria , Infecciones Urinarias , Humanos , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Estudios Prospectivos , Ucrania/epidemiología , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , Infecciones Urinarias/etiología , Infecciones Urinarias/microbiología , Procedimientos Neuroquirúrgicos , Antibacterianos/farmacología , Farmacorresistencia Bacteriana
16.
Support Care Cancer ; 32(4): 239, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512390

RESUMEN

PURPOSE: To identify the trends in the prevalence of peripherally inserted central catheter (PICC) related complications in cancer patients and explore the risk factors for complications and occurrence speed. METHODS: A total of 3573 cancer patients with PICC were recruited at 17 hospitals from 2016 to 2022. Logistic and COX regression were performed to identify influencing factors of PICC-related complications and incidence speed, respectively. RESULTS: The proportion of symptomatic PICC-related thrombosis, phlebitis, and infections reported had decreased from 59.1% (in 2017), 11.9% (in 2016), and 11.1% (in 2016) to 15.3% (in 2022), 2.9% (in 2022), and 7.4% (in 2022), and adhesive-related skin injuries and bleeding/oozing reported had increased from 4.8% (in 2016) and 0.0% (in 2016) to 45.5% (in 2022) and 3.4% (in 2022), respectively. Catheter occlusion showed a trend of first increasing and then decreasing from 2.4 (in 2016) to 12.0 (in 2020) to 5.8% (in 2022). Logistic regression showed that hospital level, nature, the patient's gender, age, diagnosis, history of deep vein catheterization, chemotherapy drug administration, and type of PICC were influencing factors of complications. COX regression showed that the patient's gender, age, diagnosis, history of deep vein thrombosis and thrombophlebitis, history of deep vein catheterization, chemotherapy drug administration, type of PICC, type of connector, and StatLock used for fixation were influencing factors of incidence speed. CONCLUSION: The composition ratios of PICC-related complications in cancer patients in China have changed in recent years. Chemotherapy drug administration was a significant risk factor accelerating the occurrence of complications. Maintenance factors had the maximum weight on the COX model, followed by patient factors. It is suggested that patients with high-risk factors be closely monitored and proper maintenance be performed to prevent and delay the occurrence of PICC-related complications.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Neoplasias , Humanos , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Prevalencia , Neoplasias/tratamiento farmacológico , Factores de Riesgo , Cateterismo Periférico/efectos adversos , Estudios Retrospectivos , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/etiología
17.
J Pediatr Gastroenterol Nutr ; 78(4): 918-926, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38451061

RESUMEN

OBJECTIVES: Patients with intestinal failure require central venous access which puts them at risk for central line-associated bloodstream infections (CLABSI). Maintaining vascular patency is critical for this population to receive nutrition support. When CLABSIs occur line salvage can help maintain vascular access. The aim of this study is to assess factors associated with safe and successful central venous catheter salvage. METHODS: Retrospective cohort study of patients with intestinal failure at two tertiary care institutions between 2012 and 2020. The study examined the rates of attempted salvage, factors associated with successful salvage, and complications associated with salvage attempts. RESULTS: Over the study period, 76 patients with intestinal failure were include while central venous access was in place. There were a total of 94 CLABSIs. Salvage was more likely to be attempted when patients were under the direct care of an intestinal rehabilitation service (95% vs. 68%, p = 0.04). The overall successful salvage rate was 91.6% (n = 77). Gram-positive, Gram-negative, and polymicrobial infections had successful salvage rates of 97%, 92%, and 94% respectively. The successful salvage rate for fungal infections was 40%. There was no difference in 30-day complication rates for hospital readmission, intensive care unit admission, and death between patients who underwent salvage attempt and those who did not. CONCLUSIONS: Central line salvage can be safely attempted for many infections in patients with intestinal failure, leading to vascular access preservation.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Enfermedades Intestinales , Insuficiencia Intestinal , Sepsis , Humanos , Niño , Estudios Retrospectivos , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Enfermedades Intestinales/terapia , Enfermedades Intestinales/complicaciones , Catéteres Venosos Centrales/efectos adversos , Catéteres Venosos Centrales/microbiología , Cateterismo Venoso Central/efectos adversos
18.
Int J Nurs Stud ; 152: 104695, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38301304

RESUMEN

BACKGROUND: Despite being a significant management decision in clinical or nursing practice, there is limited understanding of the preferences regarding risks, benefits, costs, and other attributes of patients with breast cancer when selecting peripherally inserted central catheters or totally implanted ports. The objective of this study is to investigate the preferences of patients with breast cancer who require chemotherapy when selecting an optimal central venous access device. METHODS: Data on patients' preferences for central venous access devices were collected using a face-to-face discrete choice experiment from the oncology departments of three public hospitals in China representing the eastern (Zhejiang province), central (Henan province), and western (Sichuan province) regions. The study used six attributes to describe the preferences of breast cancer patients for central venous access devices, including out-of-pocket cost, limitations in activities of daily living, catheter maintenance frequency, risk of catheter-related thrombosis, risk of catheter-related infection, and size of incision. Data were analyzed using a conditional logit model and mixed logit model. The marginal willingness to pay (mWTP) was calculated by assessing the ratio of the preference for other attributes to the preference for out-of-pocket cost. RESULTS: A total of 573 respondents completed the survey. The discrete choice experiment results showed that respondents strongly preferred a central venous access device with a catheter maintenance frequency of one time a month (vs four times a month, ß = 1.188, p < 0.001), the lower risk of catheter-related thrombosis (2 % vs 10 %, ß = 1.068; p < 0.001) and lower risk of catheter-related infection (2 % vs 8 % risk: ß = 0.824; p < 0.001). Respondents were willing to pay CNY ¥11,968.1 (US$1776.5) for a central venous access device with a catheter maintenance frequency of one time a month rather than four times a month, ¥10,753.6 (US$1596.2) for a central venous access device with 2 % thrombosis risk over one with 10 %, and ¥8302.0 (US$1232.3) for a central venous access device with 2 % infection risk over one with 8 %. Respondents with longer travel time to the hospital, younger than 50 years old, and with urban employee basic medical insurance were willing to pay more for an improvement in the attributes. CONCLUSIONS: These findings suggest that patients with breast cancer were mainly concerned with the out-of-pocket cost, catheter maintenance frequency, risk of catheter-related thrombosis and risk of catheter-related infection when choosing a central venous access device for the delivery of chemotherapy. In clinical or nursing practice, when making central venous access device recommendation for young patients and those who live far from hospitals, totally implanted ports may be a preferable choice.


Asunto(s)
Neoplasias de la Mama , Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Trombosis , Humanos , Persona de Mediana Edad , Femenino , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/tratamiento farmacológico , Cateterismo Venoso Central/efectos adversos , Prioridad del Paciente , Actividades Cotidianas , Catéteres de Permanencia/efectos adversos , Trombosis/etiología
19.
Antimicrob Resist Infect Control ; 13(1): 25, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38419046

RESUMEN

INTRODUCTION: Intravascular catheters are crucial devices in medical practice that increase the risk of healthcare-associated infections (HAIs), and related health-economic adverse outcomes. This scoping review aims to provide a comprehensive overview of published automated algorithms for surveillance of catheter-related bloodstream infections (CRBSI) and central line-associated bloodstream infections (CLABSI). METHODS: We performed a scoping review based on a systematic search of the literature in PubMed and EMBASE from 1 January 2000 to 31 December 2021. Studies were included if they evaluated predictive performance of automated surveillance algorithms for CLABSI/CRBSI detection and used manually collected surveillance data as reference. We assessed the design of the automated systems, including the definitions used to develop algorithms (CLABSI versus CRBSI), the datasets and denominators used, and the algorithms evaluated in each of the studies. RESULTS: We screened 586 studies based on title and abstract, and 99 were assessed based on full text. Nine studies were included in the scoping review. Most studies were monocentric (n = 5), and they identified CLABSI (n = 7) as an outcome. The majority of the studies used administrative and microbiological data (n = 9) and five studies included the presence of a vascular central line in their automated system. Six studies explained the denominator they selected, five of which chose central line-days. The most common rules and steps used in the algorithms were categorized as hospital-acquired rules, infection rules (infection versus contamination), deduplication, episode grouping, secondary BSI rules (secondary versus primary BSI), and catheter-associated rules. CONCLUSION: The automated surveillance systems that we identified were heterogeneous in terms of definitions, datasets and denominators used, with a combination of rules in each algorithm. Further guidelines and studies are needed to develop and implement algorithms to detect CLABSI/CRBSI, with standardized definitions, appropriate data sources and suitable denominators.


Asunto(s)
Bacteriemia , Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Infección Hospitalaria , Humanos , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/etiología , Bacteriemia/diagnóstico , Bacteriemia/epidemiología , Bacteriemia/etiología , Infección Hospitalaria/microbiología , Catéteres Venosos Centrales/efectos adversos , Catéteres Venosos Centrales/microbiología , Atención a la Salud
20.
Antimicrob Resist Infect Control ; 13(1): 15, 2024 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-38317207

RESUMEN

BACKGROUND: Continuous surveillance for healthcare-associated infections such as central venous catheter-related bloodstream infections (CVC-BSI) is crucial for prevention. However, traditional surveillance methods are resource-intensive and prone to bias. This study aimed to develop and validate fully-automated surveillance algorithms for CVC-BSI. METHODS: Two algorithms were developed using electronic health record data from 1000 admissions with a positive blood culture (BCx) at Karolinska University Hospital from 2017: (1) Combining microbiological findings in BCx and CVC cultures with BSI symptoms; (2) Only using microbiological findings. These algorithms were validated in 5170 potential CVC-BSI-episodes from all admissions in 2018-2019, and results extrapolated to all potential CVC-BSI-episodes within this period (n = 181,354). The reference standard was manual record review according to ECDC's definition of microbiologically confirmed CVC-BSI (CRI3-CVC). RESULTS: In the potential CVC-BSI-episodes, 51 fulfilled ECDC's definition and the algorithms identified 47 and 49 episodes as CVC-BSI, respectively. Both algorithms performed well in assessing CVC-BSI. Overall, algorithm 2 performed slightly better with in the total period a sensitivity of 0.880 (95%-CI 0.783-0.959), specificity of 1.000 (95%-CI 0.999-1.000), PPV of 0.918 (95%-CI 0.833-0.981) and NPV of 1.000 (95%-CI 0.999-1.000). Incidence according to the reference and algorithm 2 was 0.33 and 0.31 per 1000 in-patient hospital-days, respectively. CONCLUSIONS: Both fully-automated surveillance algorithms for CVC-BSI performed well and could effectively replace manual surveillance. The simpler algorithm, using only microbiology data, is suitable when BCx testing adheres to recommendations, otherwise the algorithm using symptom data might be required. Further validation in other settings is necessary to assess the algorithms' generalisability.


Asunto(s)
Infecciones Relacionadas con Catéteres , Catéteres Venosos Centrales , Infección Hospitalaria , Sepsis , Humanos , Catéteres Venosos Centrales/efectos adversos , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/microbiología , Infección Hospitalaria/epidemiología , Hospitalización , Sepsis/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...